RECOM Power RACM60-K 60W Multi-Purpose AC/DC Converters
RECOM Power RACM60-K 60W Multi-Purpose AC/DC Converters are 2" x 3" compact modules designed to gain the highest overall efficiency levels from universal AC inputs over the entire output load. The multi-purpose, industrial + household + medical grade AC/DC converters deliver 60W of output power from -40°C to +55°C with natural air convection only and up to +85°C with derating or forced cooling.The RACM60-K/OF features ANSI/AAMI/IEC 60601-1 medical safety and EN 60601-1-2 medical EMC certifications. This device offers 4kVAC/1 minute isolation, 2MOPP, designed to meet B and BF requirements, and is additionally certified to IEC/EN62368-1(CB Report) and IEC61558-1/-2-16 for industrial applications and IEC/EN60335-1 for household appliances. A robust built-in Class B EMC filter with sufficient margin allows Installation Class II or Class I PELV with grounded output.
A range of mechanical fixing options makes the RACM60 devices suitable for many different mounting conditions: the standard chassis mount part mates with Molex connectors, a PCB option permits direct installation in printed circuit boards, and a 2” x 4” footprint for backward compatibility with legacy designs is available on request.
Features
- Input voltage ranges from 80VAC to 264VAC or 80VAC to 305VAC
- Overvoltage category (OVC) III
- Built-in Class B EMC filter
- 2MOPP medical certified B and BF compliant
- 4000/5000m (medical/ITE) operating altitude
- Open-frame or enclosed options
- Pi-type internal input filter
- Short-circuit, overvoltage, output reverse voltage, and overcurrent protection
- Class II equipment
- Reinforced insulation grade
- Pollution degree (PD) 2
- 3-year warranty
- RoHS, REACH, and ERP compliant
Applications
- Industrial
- Household
- Medical
Specifications
- Input voltage ranges
- 80VAC to 264VAC
- 80VAC to 305VAC
- 100VAC to 277VAC nominal at 50/60Hz
- 5VDC to 48VDC output voltage range
- 1250mA to 8000mA output current range
- 40W or 60W output power options
- 89% to 90% typical efficiency
- 500mA to 1400mA maximum input current range
- 30A to 70A inrush current range
- 100mW to 120mW typical no-load power consumption range
- 47Hz to 63Hz input frequency range
- 0% minimum load
- 0.45 to 0.6 power factor range
- 100kHz typical internal operating frequency
- 200mVp-p maximum output ripple and noise
- Time
- 150ms typical start-up
- 100ms typical rise
- 12ms to 70ms minimum hold-up
- ±1.0% to ±3.0% typical output accuracy range
- ±0.05% to ±0.5% typical line regulation range
- ±0.1% to ±3.0% typical load regulation
- 3.0% or 500µs maximum transient response
- +130°C thermal shutdown, restart after cool down
- 4kVAC isolation voltage (safety certified)
- 1GΩ minimum isolation resistance
- 100pF maximum isolation capacitance
- -40°C to +85°C operating temperature range
- ±0.025/K temperature coefficient
- 95% maximum operating humidity, non-condensing
- UL 94V-0 FR4 PCB